Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Adicionar filtros

Tipo de documento
Intervalo de ano
1.
Biosensors (Basel) ; 12(7)2022 Jun 21.
Artigo em Inglês | MEDLINE | ID: covidwho-2282211

RESUMO

The presence of pathogen-specific antibodies in the blood is widely controlled by a serodiagnostic technique based on the lateral flow immunoassay (LFIA). However, its common one-stage format with an antigen immobilized in the binding zone of a test strip and a nanodispersed label conjugated with immunoglobulin-binding proteins is associated with risks of very low analytical signals. In this study, the first stage of the immunochromatographic serodiagnosis was carried out in its traditional format using a conjugate of gold nanoparticles with staphylococcal immunoglobulin-binding protein A and an antigen immobilized on a working membrane. At the second stage, a labeled immunoglobulin-binding protein was added, which enhanced the coloration of the bound immune complexes. The use of two separated steps, binding of specific antibodies, and further coloration of the formed complexes, allowed for a significant reduction of the influence of non-specific immunoglobulins on the assay results. The proposed approach was applied for the serodiagnosis using a recombinant RBD protein of SARS-CoV-2. As a result, an increase in the intensity of test zone coloration by more than two orders of magnitude was demonstrated, which enabled the significant reduction of false-negative results. The diagnostic sensitivity of the LFIA was 62.5% for the common format and 100% for the enhanced format. Moreover, the diagnostic specificity of both variants was 100%.


Assuntos
COVID-19 , Nanopartículas Metálicas , Complexo Antígeno-Anticorpo , COVID-19/diagnóstico , Ouro/química , Humanos , Imunoensaio/métodos , Limite de Detecção , Nanopartículas Metálicas/química , SARS-CoV-2 , Testes Sorológicos
2.
Biosensors (Basel) ; 13(2)2023 Feb 04.
Artigo em Inglês | MEDLINE | ID: covidwho-2225058

RESUMO

Respiratory tract infections such as the ongoing coronavirus disease 2019 (COVID-19) has seriously threatened public health in the last decades. The experience of fighting against the epidemic highlights the importance of user-friendly and accessible point-of-care systems for nucleic acid (NA) detection. To realize low-cost and multiplexed point-of-care NA detection, a swing-assisted multiplexed analyzer for point-of-care respiratory tract infection testing (SMART) was proposed to detect multiple respiratory tract pathogens using visible loop-mediated isothermal amplification. By performing hand-swing movements to generate acceleration force to distribute samples into reaction chambers, the design of the SMART system was greatly simplified. By using different format of chips and integrating into a suitcase, this system can be applied to on-site multitarget and multi-sample testing. Three targets including the N and Orf genes of SARS-CoV-2 and the internal control were simultaneously analyzed (limit of detection: 2000 copies/mL for raw sample; 200 copies/mL for extracted sample). Twenty-three clinical samples with eight types of respiratory bacteria and twelve COVID-19 clinical samples were successfully detected. These results indicate that the SMART system has the potential to be further developed as a versatile tool in the diagnosis of respiratory tract infection.


Assuntos
COVID-19 , Infecções Respiratórias , Humanos , SARS-CoV-2 , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos
3.
Sci Bull (Beijing) ; 67(18): 1823-1826, 2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: covidwho-2049898
4.
Biosensors ; 12(7):434, 2022.
Artigo em Inglês | MDPI | ID: covidwho-1894247

RESUMO

The presence of pathogen-specific antibodies in the blood is widely controlled by a serodiagnostic technique based on the lateral flow immunoassay (LFIA). However, its common one-stage format with an antigen immobilized in the binding zone of a test strip and a nanodispersed label conjugated with immunoglobulin-binding proteins is associated with risks of very low analytical signals. In this study, the first stage of the immunochromatographic serodiagnosis was carried out in its traditional format using a conjugate of gold nanoparticles with staphylococcal immunoglobulin-binding protein A and an antigen immobilized on a working membrane. At the second stage, a labeled immunoglobulin-binding protein was added, which enhanced the coloration of the bound immune complexes. The use of two separated steps, binding of specific antibodies, and further coloration of the formed complexes, allowed for a significant reduction of the influence of non-specific immunoglobulins on the assay results. The proposed approach was applied for the serodiagnosis using a recombinant RBD protein of SARS-CoV-2. As a result, an increase in the intensity of test zone coloration by more than two orders of magnitude was demonstrated, which enabled the significant reduction of false-negative results. The diagnostic sensitivity of the LFIA was 62.5% for the common format and 100% for the enhanced format. Moreover, the diagnostic specificity of both variants was 100%.

5.
Small ; 18(26): e2200854, 2022 07.
Artigo em Inglês | MEDLINE | ID: covidwho-1858927

RESUMO

The ongoing pandemic caused by severe acute respiratory syndrome coronavirus 2 is profoundly influencing the global healthcare system and people's daily lives. The high resource consumption of coronavirus disease 2019 (COVID-19) is resulting in insufficient surveillance of coinfection or resurgence of other critical respiratory epidemics, which is of public concern. To facilitate evaluation of the current coinfection situation, a microfluidic system (MAPnavi) is developed for the rapid (<40 min) and sensitive diagnosis of multiple respiratory viruses from swab samples in a fully sealed and automated manner, in which a nested-recombinase polymerase amplification and the CRISPR-based amplification system is first proposed to ensure the sensitivity and specificity. This novel system has a remarkably low limit of detection (50-200 copies mL-1 ) and is successfully applied to detect 171 clinical samples (98.5% positive predictive agreement; 100% negative predictive agreement), and the results identify 45.6% coinfection among clinical samples from patients with COVID-19. This approach has the potential to shift diagnostic and surveillance efforts from targeted testing for a high-priority virus to comprehensive testing of multiple virus sets and to greatly benefit the implementation of decentralized testing.


Assuntos
COVID-19 , Coinfecção , Vírus , COVID-19/diagnóstico , Sistemas CRISPR-Cas/genética , Coinfecção/diagnóstico , Humanos , Microfluídica , Técnicas de Amplificação de Ácido Nucleico/métodos , Sensibilidade e Especificidade
6.
Microsyst Nanoeng ; 7: 94, 2021.
Artigo em Inglês | MEDLINE | ID: covidwho-1528008

RESUMO

Coronavirus disease 2019 (COVID-19) has emerged, rapidly spread and caused significant morbidity and mortality worldwide. There is an urgent public health need for rapid, sensitive, specific, and on-site diagnostic tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. In this study, a fully integrated and portable analyzer was developed to detect SARS-CoV-2 from swab samples based on solid-phase nucleic acid extraction and reverse transcription loop-mediated isothermal amplification (RT-LAMP). The swab can be directly inserted into a cassette for multiplexed detection of respiratory pathogens without pre-preparation. The overall detection process, including swab rinsing, magnetic bead-based nucleic acid extraction, and 8-plex real-time RT-LAMP, can be automatically performed in the cassette within 80 min. The functionality of the cassette was validated by detecting the presence of a SARS-CoV-2 pseudovirus and three other respiratory pathogens, i.e., Klebsiella pneumoniae, Pseudomonas aeruginosa, and Stenotrophomonas maltophilia. The limit of detection (LoD) for the SARS-CoV-2 pseudovirus was 2.5 copies/µL with both primer sets (N gene and ORF1ab gene), and the three bacterial species were successfully detected with an LoD of 2.5 colony-forming units (CFU)/µL in 800 µL of swab rinse. Thus, the analyzer developed in this study has the potential to rapidly detect SARS-CoV-2 and other respiratory pathogens on site in a "raw-sample-in and answer-out" manner.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA